6007.0212 Interconnection Cord C13, 10 A
6007.0212 Interconnection Cord C13, 10 A
6007.0212 Interconnection Cord C13, 10 A
6007.0212 Interconnection Cord C13, 10 A

Part: 6007.0212

Config. Code: 6007.0212

Designation: Cord C13/C14 1.0m

Cord Sets 10 A, Interconnection, 1.0 m, Connector IEC C13, H05VV-F3G1.0, black

... loading ...

Free Sample Request

Connectors (Inlets/Outlets)

C13
Connector Logo
70° C
E
Connector Logo
70° C

Description

  • 1 Function:
  • appliance inlet/-outlet, Protection class I
  • Pin temperature 70 °C
  • custom specific versions on request

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.
General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA General information on the rated current and the rated voltage at EMC products
Rated Voltage Rated current The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.
Search approval information for different families
Approvals

10 A / 250 VAC; 50 Hz

Allowable Operation Temperature

-40 °C to 70 °C

IP-Protection

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.
The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects.
Details about IP protection degree can be looked up in the general product information
IP-Protection

from front side IP40 acc. to IEC 60529

Protection against electric shock

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information
Protection against electric shock

Suitable for appliances with protection class I acc. to IEC 61140

Material: Housing

PVC, black

appliance inlet/-outlet

appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

Details on connectors and their names can be found in the general product information
Appliance Couplers Mating Connectors Term explanation Special Connector Designs

C13 acc. to
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type:

Approval Logo Certificates Certification Body Description
Approval marks VDE VDE VDE Certificate Number:
Approval marks SEV SEV Schweizerischer Elektrotechnischer Verein


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Partners UL_Certification_Body Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_50_non_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

预览
 

图片 选择产品图片可显示该类型的特定型号

型号
 

型号 对应于产品系列并包括各种不同型号。总结了有关类型的说明性数据,例如在数据表中

订单编号
 

订单编号 用于下达订单的唯一料号

配置键
 

配置键 产品的配置键由复合键值构成,这些值说明不同种类的属性特性。

注释
 

注释 CAD图纸仅用于建模目的

可能的焊盘图案,采用SMD安装
 

可能的焊盘图案,采用SMD安装 CAD 模型的简略说明

IGS
 

IGS 也称为 IGES(初始图形交换规范)。用于 3D CAD 数据的公共程序独立交换格式。

Step
 

Step 也称为 STEP(产品模型数据交换标准)。适用于按照 ISO 标准进行标准化的 3D CAD 数据的公共程序独立交换格式。

Parasolid
 

Parasolid 参数化实体建模内核是一种 3D CAD 系统。它由 Unigraphics Solutions (UGS)(现为 Siemens PLM Software)内的单独业务部门开发。

DXF
 

DXF (图形交换格式)是由 Autodesk 为 CAD 数据交换而指定的文件格式,专门为 2D-CAD 程序 AutoCAD 而开发。DXF 文件按照 ASCII 标准将 CAD 模型描述为纯文本。

Short Table of Variants 6007.0212 Open complete table 6007.0212

Connector Cable Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .
This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.
This approach offers to use generic alias link to the product details:
www.schurter.xx/art/ [Order Number]
where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:
- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle
Contact us for availability on other product variants, lead-times vary:
Contact-Form Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
Type   V-Lock   Cord Type   Conductor cross section   Length [m]   Color              
 
C13 H05VV-F3G1.0 3 x 1 mm² 1.0 black 6007.0212  A  ...

Most Popular.

日期 子类别 语言 标题 下载
09/08/2018
白皮书 英语 (English) White Paper Cord retention
Mating Inlets/Plugs (84)

[Swipe to the left and right for more options]

6100-3

6100-3, Mounting: Screw, Solder terminals or quick connect terminals, Appliance Inlet: IEC C14

6100-4

6100-4, Mounting: Snap-in, Solder terminals or quick connect terminals, Appliance Inlet: IEC C14

6102-3

6102-3, Mounting: Screw, Solder terminals or quick connect terminals, Appliance Inlet: IEC C18

6102-5

6102-5, Mounting: Snap-in, Solder terminals or quick connect terminals, Appliance Inlet: IEC C18

6150

G-Stecker, Mounting: Appliance Inlet : IEC C14 Without fuse holder

1061

1061, Mounting: Snap-in, Solder, Quick Connect or Screw Terminals, Appliance Inlet: IEC C14

6010

6010, Mounting: Snap-in, Solder, quick-connect, screw, PCB, Appliance Inlet: IEC C14

6015

6015, Mounting: Snap-in, Solder, quick-connect, screw, PCB, Appliance Inlet: IEC C18

0711

0711, Mounting: Snap-in, 0.8 mm, Solder, Appliance Inlet: IEC C14

6048

6048, Mounting: Screw, Appliance Inlet: IEC C14

6061

6061, Mounting: Screw, Appliance Inlet: IEC C14

6061-G

6061-G, Mounting: Screw, Appliance Inlet: IEC C14

6130

6130, Mounting: Snap-in, Appliance Inlet, IEC C14, For PCB mounting, IP30, Meets the glow wire test acc. IEC 60335-1 edition 4, 7/7.3, Suitable for appliances with protection class I

8843.ZP30

8843.ZP30, Mounting: Screw, For PCB mounting, Appliance Inlet: IEC C14

GSP1

GSP1, Mounting: Screw, Appliance Inlet, IEC C14, For PCB mounting, IP40, Quick connect terminals 4.8 x 0.8 mm angled or straight, Suitable for appliances with protection class I or II

GSP2

GSP2, Mounting: Sandwich, Appliance Inlet, IEC C14, For PCB mounting, IP40, angled to pin axis, Suitable for appliances with protection class I or II

0712

0712-PQ, Mounting: Snap-in, Front Side, Solder terminal (4.8 x 0.8 mm), 1x Appliance Outlet: IEC F

4741

4741, Mounting: 2x Appliance Outlet: IEC F

4747

4747, Mounting: 4x Appliance Outlet: IEC F

4740

4740, Mounting: 6x Appliance Outlet: IEC F

5123

5123, Mounting: Screw, Front-/Rear-Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Themoplast / steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I or II

GRF2

GRF2, Mounting: Rear Side, With EMC-shield and without line filter, 10 A, Plug Connector, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

5110

5110, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Thermoplastic Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I

5120

5120, Mounting: Screw with plastic flange, Front-/Rear-Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Themoplast / steel tin-plated Appliance Inlet: IEC C14, Suitable for appliances with protection class I or II

KFS

KFS, Mounting: Screw, Front Side, Filter: Standard Version, Without fuse holder: 10 A, Appliance Inlet: IEC C14, prewired

4732

4732, Mounting: Power Cord, Plug: IEC E, Cable

4735

4735, Mounting: Power Cord, Plug: IEC E, Cable

4733

4733, Mounting: Power Cord, Plug: IEC E, Cable

4736

4736, Mounting: Power Cord, Plug: IEC E, Cable

P685

p685, Mounting: Power Cord, Plug: IEC E, Cable

DD11

DD11, Mounting: Screw-on mounting, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 4.8 x 0.8 mm, Appliance Inlet: IEC C14, With or without protection cover, Fuseholder: 1 or 2 pole, Suitable for appliances with protection class I

DD21

DD21, Mounting: Screw-on mounting Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, additional quick connect 4.8 x 0.8 mm Appliance Inlet: IEC C14, Fuseholder: 1 or 2 pole

DC11

DC11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 1 or 2 pole, Quick connect terminals 4.8 x 0.8 mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II

KEB1

KEB1, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated, 1-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I

KEB2

KEB2, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I

DC21

DC21, Mounting: Screw Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 4.8 x 0.8 mm Appliance Inlet: IEC C14, Without fuse holder:

KM

KM, Mounting:Quick connect terminals 4.8 x 0.8 mm, Fuseholder: 1 or 2 pole, Rocker switch, non-illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I or II

KD

KD, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Voltage Selector: 2-4 digits, Fuseholder: 1 or 2 pole, Rocker switch, non-illuminated, 2-pole, V-Lock cord retaining, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I

KG

KG, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Voltage Selector: Fuseholder: 1 or 2 pole, Rocker switch, non-illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, partially wired, Suitable for appliances with protection class I

6765

6765, Power Entry ModuleC14, 70°C, version: L: N: ground: : fuseholder: color: design: dimension S: features:

6762

6762, Power Entry ModuleC14, 70°C, version: L: N: ground: : fuseholder: color: design: dimension S: features:

KP (Outlet)

IEC Appliance Inlet C14 with Appliance Outlet F

KP (Switch)

, Mounting: Screw, mm, : 2-pole, : IEC C14,

KP (FH)

KP (SiHa), Mounting: mm, Fuseholder: 1 or 2 pole, Appliance Inlet: IEC C14, Quick connect terminals 4.8 x 0.8 mm

Felcom 64

Felcom 64, Mounting: 0 mm, Fuseholder: Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm, Rocker switch: 2-pole non-illuminated, Appliance Inlet: IEC C14, Power Entry Module

6250 / 6255

Si-Ha, Mounting: Appliance Inlet : IEC C14 Fuseholder 1 or 2 pole

GSF1

GSF1, Mounting: Fuse holder: optional, 1 or 2 pole, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

GSF2

GSF2, Mounting: Snap-in, Appliance Inlet: IEC C14, Fuseholder: 1 or 2 pole, Solder terminals or quick connect terminals : black, Suitable for appliances with protection class I or II

KEA

KEA, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Voltage Selector: 2-4 digits, Fuseholder: 1 or 2 pole, Appliance Inlet: IEC C14, 250 VAC, prewired or unwired, Suitable for appliances with protection class I

KEA-Print

KEA-Print, Mounting: Screw, Front-/Rear-Side, Fuse holder: 1 or 2 pole, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

6200

6200, Mounting:Screw, Solder terminals or quick connect terminals, Fuseholder: 1-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I

6202

6202, Mounting:Screw, Solder terminals or quick connect terminals, Fuseholder: 1-pole, Appliance Inlet: IEC C18, 250 VAC, prewired, Suitable for appliances with protection class II

6205

6205, Mounting:Screw, Solder terminals or quick connect terminals, Fuseholder: 1-pole, Appliance Inlet: IEC C14, 250 VAC, unwired, Suitable for appliances with protection class I

1062

1062, Power Entry ModuleC14, 70°C, version: L: N: ground: : fuseholder: color: design: dimension S: features:

1064

1064, Power Entry ModuleC14, 70°C, version: L: N: ground: : fuseholder: color: design: dimension S: features:

6220

6220, Mounting:Screw, Solder terminals or quick connect terminals, Fuseholder: 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I

4707

4707, Mounting:Screw, Solder terminals or quick connect terminals, Fuseholder: 1 or 2 pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I or II

8842/8843

8842/8843, Mounting: Screw, Appliance Inlet: IEC C14, Fuseholder: 1 or 2 pole, : black, Suitable for appliances with protection class I or II

KEC

KEC, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Voltage Selector: 2-4 digits, Fuseholder: 1 or 2 pole, Appliance Inlet: IEC C14, 250 VAC, prewired or unwired, Suitable for appliances with protection class I

KE

KE, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Voltage Selector: Fuseholder: 1 or 2 pole, Appliance Inlet: IEC C14, 250 VAC, prewired or unwired, Suitable for appliances with protection class I

DG12

DG12, Mounting : Screw, 8 mm, 15 A, prewired, Standard and Medical Version, Appliance Inlet: IEC C14 C18, Circuit Breakers TA35: DG12, Suitable for appliances with protection class I or II

DD14

DD14, Mounting: Screw-on mounting, Front Side, Filter, Standard and Medical Version, Fuseholder:1 or 2 pole, 10 A, Rocker switch: 2-pole, non-illuminated Appliance Inlet: IEC C14, prewired

KFB1

KFB1, Mounting: Screw, Front Side, Filter: Standard Version, Without fuse holder: 10 A, Rocker switch: 1-pole, Appliance Inlet: IEC C14, prewired

DA22

DA22 Mounting: Screw-on mounting, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Fuseholder: 1 or 2 pole, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

KFB2

KFB2, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Rocker switch: 2-pole, Appliance Inlet: IEC C14, prewired

DC12

DC12, Mounting: Screw, Front-/Rear-Side, Filter, Standard and Medical Version, Without fuse holder:10 A, Rocker switch: 1 or 2 pole, non-illuminated or illuminated Appliance Inlet: IEC C14, prewired

DC22

DC22 Mounting: Screw, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Without fuse holder: Rocker switch: 1 or 2 pole, non-illuminated or illuminated, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

DD12

DD12, Mounting: Screw-on mounting, Front Side, Filter, Standard and Medical Version, Fuseholder:1 or 2 pole, 10 A, Rocker switch: 2-pole, non-illuminated Appliance Inlet: IEC C14, prewired

DD22

DD22 Mounting: Screw-on mounting, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Fuseholder: 1 or 2 pole, Rocker switch: 2-pole, non-illuminated, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

KMF

KMF, Mounting: Front Side, Filter: Standard and Medical Version, Fuseholder: 1 or 2 pole, Front Side, 10 A, 2-pole, Appliance Inlet: IEC C14, prewired

CD

CD, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuseholder: 1 or 2 pole, Front Side, 10 A, 2-pole, Voltage Selector: step, 2-4 digits, Appliance Inlet: IEC C14, prewired

CG

CG, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuseholder: 1 or 2 pole, Front Side, 10 A, 2-pole, Voltage Selector: series-parallel, Appliance Inlet: IEC C14, partially wired

FKH

FKH, Mounting: Screw, Front Side, Filter: Standard Version, Fuseholder: 1-pole, Front Side, 10 A, 2-pole, Thermoplastic Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I

FKI

FKI, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuseholder: 2-pole, Front Side, 10 A, 2-pole, Thermoplastic Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I

FKHD

FKHD, Mounting: Screw, Front Side, Filter: Standard Version, Fuseholder: 1-pole, Front Side, 10 A, 2-pole, Thermoplastic Appliance Inlet: IEC C14, Suitable for appliances with protection class I

FKID

FKID, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuseholder: 2-pole, Front Side, 10 A, 2-pole, Thermoplastic Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I

Felcom 54

Felcom 54, Mounting: mm, Front Side, Filter: Standard Version, Fuseholder: 1 or 2 pole, Front Side, 10 A, Rocker switch: 2-pole, Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm, Appliance Inlet: IEC C14

GRF4

GRF4, Mounting: Screw, Rear Side, With EMC-shield and line filter, Standard and Medical Version, 10 A, Appliance Inlet: IEC C14, Suitable for appliances with protection class I

KFA

KFA, Mounting: Screw, Front-/Rear-Side, Filter: Standard and Medical Version, Fuseholder: 1 or 2 pole, Front Side, 10 A, Voltage Selector: step, 3 pos., Appliance Inlet: IEC C14, prewired

KFC

KFC, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuseholder: 1 or 2 pole, Front Side, 10 A, Voltage Selector: step, 3 pos., Appliance Inlet: IEC C14, prewired

CE

CE, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuseholder: 1 or 2 pole, Front Side, 10 A, Voltage Selector: series-parallel, Appliance Inlet: IEC C14, partially wired

5200

5200, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuseholder: 1-pole, Front Side, 10 A, Thermoplastic Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I

5220

5220, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Fuseholder: 2-pole, Front Side, 10 A, Thermoplastic Appliance Inlet: IEC C14, prewired, Suitable for appliances with protection class I

5707

5707, Mounting: Screw, Front-/Rear-Side, Filter: Standard and Medical Version, Fuseholder: 1 or 2 pole, Front Side, 8 A, Appliance Inlet: IEC C14, Suitable for appliances with protection class I or II

Mating Outlets/Connectors (18)

[Swipe to the left and right for more options]

6600-5

6600-5, Mounting: Snap-in version, Appliance Outlet: IEC F, For PCB mounting, 10 A, Suitable for appliances with protection class I

6610-5

6610-5, Mounting: Snap-in version, Appliance Outlet: IEC F, IDC terminals, 10 A, Suitable for appliances with protection class I

6600-3

6600-3, Mounting: Screw-on mounting, Appliance Outlet: IEC F, Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I

6610

6610, Mounting: Snap-in version, Appliance Outlet: IEC F, IDC terminals, 10 A, Suitable for appliances with protection class I

5098

5098, Mounting: Screw-on mounting, Appliance Outlet: IEC F, Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I or II

6600-4

6600-4, Mounting: Snap-in version, Appliance Outlet: IEC F, Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I

4721

4721, Mounting: Screw-on mounting, Appliance Outlet: IEC F, Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I

4723

4723, Mounting: Snap-in version, Appliance Outlet: IEC F, Solder terminals or quick connect terminals, 10 A, Suitable for appliances with protection class I

6650

G-Steckdose, Mounting: Appliance Outlet : IEC F Without fuse holder

5001

5001, Mounting: Screw-on mounting from rear-side, For PCB mounting, : F

4751

4751, Mounting: Snap-in, Front Side, Solder pin or quick connect terminals 6.3 x 0.8 or 4.8 x 0.8 mm, x Appliance Outlet: IEC F

4741

4741, Mounting: 2x Appliance Outlet: IEC F

0909

0909, Mounting: Snap-in, Front Side, Solder terminals, 7x Appliance Outlet: IEC F

4752

4752, Mounting: Snap-in, Front Side, Solder terminals or quick connect terminals, 4x Appliance Outlet: IEC F

4748

4748, Mounting: 4x Appliance Outlet: IEC F

KP (Outlet)

IEC Appliance Inlet C14 with Appliance Outlet F

4719

4719, Mounting: Snap-in, mm, Fuseholder: 1-pole, Appliance Outlet: IEC F, with or without neon indicator, Suitable for appliances with protection class I

Felcom 54

Felcom 54, Mounting: mm, Front Side, Filter: Standard Version, Fuseholder: 1 or 2 pole, Front Side, 10 A, Rocker switch: 2-pole, Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm, Appliance Inlet: IEC C14

Mating Inlets/Plugs shuttered (1)

[Swipe to the left and right for more options]

KM

KM, Mounting:Quick connect terminals 4.8 x 0.8 mm, Fuseholder: 1 or 2 pole, Rocker switch, non-illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I or II