• 新闻
  • 联系SCHURTER
  • safe&easy
  • DE EN 中文
结果 out of 阅读更多 产品 查看所有结果

分享

分享此页面

您可以通过发送所选页面的URL与他人共享此页面。

Email LinkedIn
C20F Screw-on mounting from front side en IM0005206
Screw-on mounting
from front side
C20F Snap-in mounting from front side en IM0005241
Snap-in mounting
from front side
C20F Screw-on mounting from rear side with wires  stranded  en IM0005204
Screw-on mounting
from rear side
with wires (stranded)
C20F Screw Rear Side en IM0005205
Screw-on mounting from rear side
C20F Screw-on mounting from front side en IM0005206
C20F Snap-in mounting from front side en IM0005241
C20F Screw-on mounting from rear side with wires  stranded  en IM0005204
C20F Screw Rear Side en IM0005205

Series: C20F

IEC Appliance Inlet C20 with Filter, Front or Rear Side Mounting

Free Sample Request

28 Variants


Connectors (Inlets/Outlets)

C20
Connector Logo
70° C

Description

  • Panel mount: Screw-on version from front or rear side, snap-in version from front side
  • 2 Functions: Appliance Inlet Protection class I, Line filter in standard and medical version
  • Solder, quick connect or wires (stranded)

Unique Selling Proposition

  • Attractive flat front design
  • Highly resistant since fully potted
  • Various filter variants
  • V-Lock cord retaining

Characteristics

  • Compact design with optimal shielding
    Suitable for assembly in metal plated plastic housings
  • Version with class X1 and X2 (standard version) capacitors
  • Universal line filter for standard applications
  • Suitable for use in equipment according to IEC/UL 62368-1
    Suitable for use in medical equipment according to IEC/UL 60601-1

Other versions on request

  • 16A according to UL
  • Capacity CX 330 nF

Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.

Ratings IEC

Ratings IEC


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.
General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA General information on the rated current and the rated voltage at EMC products
Rated Voltage Rated current The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.
Search approval information for different families
Approvals

16 A @ Ta 40 °C / 250 VAC; 50 Hz

Ratings UL/CSA

Ratings UL


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.
General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA General information on the rated current and the rated voltage at EMC products
Rated Voltage Rated current The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.
Search approval information for different families
Approvals

20 A @ Ta 40 °C / 250 VAC; 60 Hz

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.
Leakage Current

standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.
Dielectric Strength

> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)

Impulse Withstand Voltage

Impulse Withstand Voltage


Information about the maximum permissible surge voltage. Thus, the operating limit with high energy pulses, such as Lightning strikes, short circuits or switching operations tested and classified.
Impulse Withstand Voltage

> 2.5 kV between L-N (CX2)
> 4 kV between L-N (CX1)
> 5 kV between L/N-PE (Cy2)
voltage (1.2/50 μs)

Allowable Operation Temperature

-25 °C to 85 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

25/085/21 acc. to IEC 60068-1

IP-Protection

IP-Protection


The IP code consists of a two-digit number, which indicates the respective degree of protection.
The first digit specifies the protection from the penetration of foreign objects, the second digit the protection from water penetration with harmful effects.
Details about IP protection degree can be looked up in the general product information
IP-Protection

from front side IP40 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information
Protection against electric shock

Suitable for appliances with protection class I acc. to IEC 61140

Terminal

Terminals


Terminals according IEC Standard.

Detailed information about terminals can be looked up in the date sheet or in the general product information.
Terminal

Solder, quick connect or wires (stranded)

Panel Thickness S

Panel Thickness S



See details in drawing
Snapper

Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 1 mm to 3 mm

Material: Housing

Thermoplastic, black, UL 94V-0

appliance inlet/-outlet

appliance inlet/-outlet


Connector type according to IEC 60320-1 resp. IEC 60320-2-2, UL498, CSA C22.2 no.42

Details on connectors and their names can be found in the general product information
Appliance Couplers Mating Connectors Term explanation Special Connector Designs

C20 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 16 A, Protection Class I

Line Filter

Filter Type


Filter classification according leakage current for easy reading:
Standard: < 0.5 mA
Medical: < 0.1 mA

Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8
Technical Details

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.
MTBF

> 3'000'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: C20F

Approval Logo Certificates Certification Body Description
Approval marks VDE VDE VDE Certificate Number: 104884
Approval marks cURus UL UL File Number: E72928
Approval marks CQC CQC CQC Certificate Number: CQC18001191999


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes
Partners IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Partners IEC_Certification_Body Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements
Partners UL_Certification_Body Designed according to UL 498 Standard for Attachment Plugs and Receptacles
Partners UL_Certification_Body Designed according to UL 1283 Electromagnetic interference filters
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Partners CSA_Certification_Body Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 62368 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.
Partners IEC_Certification_Body Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
 V_Lock_Logo SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

预览
 

图片 选择产品图片可显示该类型的特定型号

型号
 

型号 对应于产品系列并包括各种不同型号。总结了有关类型的说明性数据,例如在数据表中

订单编号
 

订单编号 用于下达订单的唯一料号

配置键
 

配置键 产品的配置键由复合键值构成,这些值说明不同种类的属性特性。

注释
 

注释 CAD图纸仅用于建模目的

可能的焊盘图案,采用SMD安装
 

可能的焊盘图案,采用SMD安装 CAD 模型的简略说明

IGS
 

IGS 也称为 IGES(初始图形交换规范)。用于 3D CAD 数据的公共程序独立交换格式。

Step
 

Step 也称为 STEP(产品模型数据交换标准)。适用于按照 ISO 标准进行标准化的 3D CAD 数据的公共程序独立交换格式。

Parasolid
 

Parasolid 参数化实体建模内核是一种 3D CAD 系统。它由 Unigraphics Solutions (UGS)(现为 Siemens PLM Software)内的单独业务部门开发。

DXF
 

DXF (图形交换格式)是由 Autodesk 为 CAD 数据交换而指定的文件格式,专门为 2D-CAD 程序 AutoCAD 而开发。DXF 文件按照 ASCII 标准将 CAD 模型描述为纯文本。

C20F
C20F.0001 C20F.0002 C20F.0003 C20F.0004 C20F.0101 C20F.0102 C20F.0103 C20F.0104
C20F.XX0X CAD-Model shows variation terminal 6.3x0.8 mm
C20F
C20F.0011 C20F.0012 C20F.0013 C20F.0014 C20F.0111 C20F.0112 C20F.0113 C20F.0114
C20F.XX1X CAD-Model shows variation Terminal 6.3x0.8 mm
C20F
C20F.0021 C20F.0022 C20F.0023 C20F.0024 C20F.0025 C20F.0026 C20F.0121 C20F.0122 C20F.0123 C20F.0124 C20F.0125 C20F.0126 C20F.0221 C20F.0222 C20F.0223 C20F.0224
C20F.XX2X CAD-Model shows variation terminal 6.3x0.8 mm

Dimension [mm]

Screw-on from front side

* Solder terminal: identical outer dimensions

Screw-on mounting from rear side with metal flange

Snap-in mounting from front side

Screw-on mounting from front side with flexible wire


Diagrams

Standard Version

1) Line
2) Load
Medical Version (M5)

1) Line
2) Load

Technical Data of Filter-Components

Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ]
16 Standard Version 2 x 0.3 100 2.2 1
16 Medical Version (M5) 2 x 0.3 100 - 1
16 Medical Version (M80) 2 x 0.3 100 0.47 1

Attenuation Loss

20 A

20 A


Short Table of Variants C20F Open complete table C20F

Rated Current IEC

Rated Current IEC


Normally, the maximum rated current is given in accordance with the admission test of the respective inspection. Accordingly, the international test requirements apply primarily according to the IEC standard. Alternatively, the rated current details are briefly UL also specified by the test requirements of the American testing by Underwriters Laboratories.

  In the meantime it has been shown that the nominal current range of a product is of interest, so we will show newly the minimum value. This corresponds, if present, the smallest approved rating of the product. Otherwise, a blank value or also the value 0 is used.

It was also necessary to distinguish between the rated currents for alternating current (AC) and direct current (DC), since different products may be used in both applications.

Rated Current UL

Rated Current UL


Normally, the maximum rated current is given in accordance with the admission test of the respective inspection. Accordingly, the international test requirements apply primarily according to the IEC standard. Alternatively, the rated current details are briefly UL also specified by the test requirements of the American testing by Underwriters Laboratories.

  In the meantime it has been shown that the nominal current range of a product is of interest, so we will show newly the minimum value. This corresponds, if present, the smallest approved rating of the product. Otherwise, a blank value or also the value 0 is used.

It was also necessary to distinguish between the rated currents for alternating current (AC) and direct current (DC), since different products may be used in both applications.

Filter-Type

Filter Type


Filter classification according leakage current for easy reading:
Standard: < 0.5 mA
Medical: < 0.1 mA

Order Number

V-Lock


V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset.
Details of the V-Lock system can be found in the general product information.
General Product Information V-Lock

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:
- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle
Contact us for availability on other product variants, lead-times vary:
Contact-Form Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
[A]   [A]              
 
16 20 Standard Version C20F.0111  A  ...
16 20 Standard Version C20F.0113 ...
16 20 Standard Version C20F.0011 ...
16 20 Standard Version C20F.0013 ...
16 20 Standard Version C20F.0101  A  ...
16 20 Standard Version C20F.0103 ...
16 20 Standard Version C20F.0001  A  ...
16 20 Standard Version C20F.0003 ...
16 20 Standard Version C20F.0221 ...
16 20 Standard Version C20F.0023 ...
16 20 Standard Version C20F.0223 ...
16 20 Standard Version C20F.0121 ...
16 20 Standard Version C20F.0123 ...
16 20 Standard Version C20F.0021 ...
16 20 Medical Version (M5) C20F.0112 ...
16 20 Medical Version (M5) C20F.0114 ...
16 20 Medical Version (M5) C20F.0012 ...
16 20 Medical Version (M5) C20F.0014 ...
16 20 Medical Version (M5) C20F.0102 ...
16 20 Medical Version (M5) C20F.0104 ...
16 20 Medical Version (M5) C20F.0002  A  ...
16 20 Medical Version (M5) C20F.0004 ...
16 20 Medical Version (M5) C20F.0022 ...
16 20 Medical Version (M5) C20F.0222 ...
16 20 Medical Version (M5) C20F.0024 ...
16 20 Medical Version (M5) C20F.0224 ...
16 20 Medical Version (M5) C20F.0122 ...
16 20 Medical Version (M5) C20F.0124 ...

Most Popular.

Wire length: 150 mm

日期 子类别 语言 标题 下载
21/02/2019
产品彩页 英语 (English) Flyer Components and Solutions for Medical Equipment
04/02/2019
白皮书 英语 (English) White Paper Safety in medical Equipment
04/01/2019
PCS 英语 (English) C20F Snap-In
04/01/2019
PCS 英语 (English) C20F Screw
08/10/2018
PCN 英语 (English) C20F PCN Change of product and packaging label
09/08/2018
产品彩页 英语 (English) Flyer V-Lock cord-retention safeguard
09/08/2018
白皮书 英语 (English) White Paper Cord retention
13/07/2018
PCN 英语 (English) All connectors PG06 PCN Change of configuration code PG06
06/04/2018
白皮书 英语 (English) White Paper Mating Connectors English
09/03/2018
PCN 英语 (English) C20F PCN Change of production site
24/11/2017
白皮书 英语 (English) White Paper Leakage currents
10/11/2017
PCN 英语 (English) C20F PCN change of material and V-Lock standard
09/09/2017
白皮书 英语 (English) White Paper Power Consumption
12/07/2017
PCN 英语 (English) C20F PCN V-Lock as standard feature and change of socket material
Alternative: version without line filter (2)

[Swipe to the left and right for more options]

Mating Outlets/Connectors (3)

[Swipe to the left and right for more options]

4795

4795, Mounting: Power Cord, Cable Connector: IEC C19

4790

4790, Mounting: Power Cord, Screw Connector: IEC C19

0104U

0104U, Mounting: Power Supply Cord, Screw clamps Connector: IEC C19

Mating Outlets/Connectors shuttered (1)

[Swipe to the left and right for more options]

VAC19KS

VAC19KS, Overview, V-Lock cord retaining, diverse Connector IEC C19, diverse, black

Accessories (6)

[Swipe to the left and right for more options]

Wire Harness

Wire harness for SCHURTER products

Assorted Covers

Rear Cover

Cord retaining kits

Cord retaining strain relief

4700.0010

Countersunk, K

4700.0011

Flat head, L


us.schurter.com
cns
cns
chi-CN