• 新闻
  • 联系SCHURTER
  • safe&easy
  • DE EN 中文
结果 out of 阅读更多 产品 查看所有结果

分享

分享此页面

您可以通过发送所选页面的URL与他人共享此页面。

Email LinkedIn
FMAD FMAD - 1-stage filter en IM0005151

Series: FMAD

1-stage filter for 3-phase systems with neutral conductor

Free Sample Request

13 Variants


Description

  • Terminals for three phases, neutral conductor and ground

Rated Current

Rated Current


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.
General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA General information on the rated current and the rated voltage at EMC products
Rated Voltage Rated current The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.
Search approval information for different families
Approvals

6 - 550 A

Rated voltage

Rated Current


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.
General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA General information on the rated current and the rated voltage at EMC products
Rated Voltage Rated current The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.
Search approval information for different families
Approvals

277/480 VAC, 50/60 Hz

Approval for

Approval for


Approvals indicate the conformity of the products with the national testing institution requirements by listing of the relevant approval logos.

The link leads you to the search mask where you can query for certificates of the selected products.
Approvals
Detailed information about Approvals will be documented in the general product informations.
Details about Approvals

6 - 550 A @ 40 (75) °C / 277/480 VAC

Overload Current

1.5 x Ir for 1 minute, per hour

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.
Leakage Current

industrial < 15 mA (440 V / 50 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.
Dielectric Strength

277/480 VAC:
2.25 kVDC between L-L
1.7 kVDC between L-N
3 kVDC between L-PE
2.7 kVDC between N-PE
Test voltage (2 sec)

Number of Filter Stages

Filter Stages


Quality of a filter

1-stage

Weight

0.95 - 24.5 kg

Material: Housing

Metal 

Sealing Compound

UL 94V-0 

Mounting

Screw-on mounting on chassis, from top

Terminal

Terminal


AMP = standardized connector systems and contacts
Abbreviation for "Zero Insertion Force". The so-called ZIF connector takes the flexprint cable without effort, mostly with locking. The advantage of this connector is the gentle treatment of the pin

Screw clamps 

Operating Temperature

-25 °C to 100 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

25/100/21 acc. to IEC 60068-1

Degree of Protection

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

IP20 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information
Protection against electric shock

Suitable for appliances with protection class I acc. to IEC 61140

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.
MTBF

> 200'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: FMAD

Approval Logo Certificates Certification Body Description
Approval marks cURus UL UL File Number: E72928


Product standards

Product standards that are referenced

Organization Design Standard Description
Partners IEC_Certification_Body Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference
Partners UL_Certification_Body Designed according to UL 1283 Electromagnetic interference filters


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/863
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

预览
 

图片 选择产品图片可显示该类型的特定型号

型号
 

型号 对应于产品系列并包括各种不同型号。总结了有关类型的说明性数据,例如在数据表中

订单编号
 

订单编号 用于下达订单的唯一料号

配置键
 

配置键 产品的配置键由复合键值构成,这些值说明不同种类的属性特性。

注释
 

注释 CAD图纸仅用于建模目的

可能的焊盘图案,采用SMD安装
 

可能的焊盘图案,采用SMD安装 CAD 模型的简略说明

IGS
 

IGS 也称为 IGES(初始图形交换规范)。用于 3D CAD 数据的公共程序独立交换格式。

Step
 

Step 也称为 STEP(产品模型数据交换标准)。适用于按照 ISO 标准进行标准化的 3D CAD 数据的公共程序独立交换格式。

Parasolid
 

Parasolid 参数化实体建模内核是一种 3D CAD 系统。它由 Unigraphics Solutions (UGS)(现为 Siemens PLM Software)内的单独业务部门开发。

DXF
 

DXF (图形交换格式)是由 Autodesk 为 CAD 数据交换而指定的文件格式,专门为 2D-CAD 程序 AutoCAD 而开发。DXF 文件按照 ASCII 标准将 CAD 模型描述为纯文本。

FMAD
FMAD-0931-0810 FMAD-0931-1610
FMAD-0931-XXXX
FMAD
FMAD-09KQ-H650
FMAD-09KQ-XXXX
FMAD
FMAD-0956-H310
FMAD-0956-XXXX
FMAD
FMAD-0955-H210
FMAD-0955-XXXX
FMAD
FMAD-0954-H110
FMAD-0954-XXXX
FMAD
FMAD-0953-6410
FMAD-0953-XXXX
FMAD
FMAD-0937-8010
FMAD-0937-XXXX
FMAD
FMAD-0934-3610 FMAD-0934-5010
FMAD-0934-XXXX
FMAD
FMAD-0932-2510
FMAD-0932-XXXX
FMAD
FMAD-0932-1610
FMAD-0932-XXXX
FMAD
FMAD-0924-0610
FMAD-0924-XXXX

Dimension [mm]

Case 24-4

1) Line
2) Load
3) Nut torque 3...4 Nm
Case 31-4

Case 32-4

Case 32-8

Case 34-4

Case 37-4

Case 53-4

1) Line
2) Load
3) Tightening torque 3...4 Nm
4) Tightening torque 10...17 Nm
5) Do not unscrew lock-nut
Case 54-4

Case 55-4

1) Line
2) Load
3) Nut torque 14...30 Nm
4) Do not unscrew lock-nut
Case 56-4

Case KQ

1) Line
2) Load
3) Torsional stress at flat copper max. 25 Nm

Diagrams

1) Line

Derating Curves

Permissible Working Current as a Function of Ambient Temperature

Admissible operating current in % of In
Ambient air temperature Ta °C


Technical data to the filter components

Rated Current @ Tu 40°C (75°C) [A] L [mH] C1 [μF] C2 [μF] C3 [nF] C4 [nF] C5 [μF] C6 [μF]

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .
This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.
This approach offers to use generic alias link to the product details:
www.schurter.xx/art/ [Order Number]
where the following variables are used:
- xx is the country specific domain
- [Order Number]

R1 [MΩ] R2 [MΩ] R3 [MΩ] R4 [MΩ] Filter-Type
6 (4.8) 9 1.0 - 100 10 2.2 - - - 1 2.2 Standard Version
8 (5) 8 1.0 - 100 10 2.2 - - - 1 2.2 Standard Version
16 (9.5) 5 1.0 - 100 10 2.2 - - - 1 2.2 Standard Version
25 (13) 2.6 4.4 1 10 47 4.4 1 - 1 1 2.2 Standard Version
36 (19) 1.8 4.4 1 10 47 4.4 1 2.2 1 1 - Standard Version
50 (32) 0.8 4.4 1 10 100 4.4 1 2.2 1 1 - Standard Version
64 (34) 0.6 4.4 1 10 100 4.4 1 2.2 1 1 - Standard Version
80 (43) 0.9 6.6 1 47 100 6.6 1 2.2 1 1 - Standard Version
110 (66) 0.5 6.6 1 47 100 6.6 1 2.2 1 1 - Standard Version
180 (95) 0.25 6.6 1 47 100 6.6 1 2.2 1 1 2.2 Standard Version
250 (120) 0.2 11 1 100 100 11 1 2.2 0.5 0.5 2.2 Standard Version
550 (320) 0.2 10 1 100 100 10 1 2.2 0.5 0.5 2.2 Standard Version

Attenuation Loss

6A (FMAD-0924-0610)

8A (FMAD-0931-0810)

16A (FMAD-0931-1610)
16A (FMAD-0932-1610)
25A (FMAD-0932-2510)

36A (FMAD-0934-3610)

50A (FMAD-0934-5010)

64A (FMAD-0953-6410)

80A (FMAD-0937-8010)

110A (FMAD-0954-H110)

180A (FMAD-0955-H210)

250A FMAD-0956-H310

550A FMAD-09KQ-H650


Short Table of Variants FMAD Open complete table FMAD

Rated Current @ Tu 40°C (75°C) [A] Leakage Current [mA] @ 440V, 60Hz 1) Tripped Power Dissipation [W] Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .
This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.
This approach offers to use generic alias link to the product details:
www.schurter.xx/art/ [Order Number]
where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:
- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle
Contact us for availability on other product variants, lead-times vary:
Contact-Form Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links refers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.
The stock availability at the distributors may also be called up separately and the desired product manually entered.
Stock Check Distributor

...
 
6 (4.8) 1.3 3.9 FMAD-0924-0610 ...
8 (5) 1.3 9 FMAD-0931-0810  A  ...
16 (9.5) 1.3 15.4 FMAD-0931-1610  A  ...
16 (9.5) 1.3 15.4 FMAD-0932-1610 ...
25 (13) 8.4 11.5 FMAD-0932-2510  A  ...
36 (19) 8.4 21 FMAD-0934-3610  A  ...
50 (32) 9.0 20 FMAD-0934-5010  A  ...
64 (34) 9.0 27 FMAD-0953-6410  A  ...
80 (43) 9.7 39 FMAD-0937-8010  A  ...
110 (66) 9.7 58 FMAD-0954-H110  A  ...
180 (95) 9.7 51 FMAD-0955-H210 ...
250 (120) 10.4 62.5 FMAD-0956-H310 ...
550 (320) 10.4 36 FMAD-09KQ-H650 ...

Most Popular.

10) Connection straps for M10

6A version: packing unit 2 pcs.

1) Nominal leakage current acc. to IEC60950 - 5.2.5. under normal operating conditions. Note: worst case leakage current acc. to IEC60950 - Annex G4 (situation with two interrupted lines) can be much higher.

日期 子类别 语言 标题 下载
21/02/2019
产品彩页 英语 (English) Leaflet Components & Solutions for Renewable Energy Technology
24/11/2017
白皮书 英语 (English) White Paper Leakage currents
We recommend for new applications the type (1)

[Swipe to the left and right for more options]


us.schurter.com
cns