• Newsroom
  • Contact
  • safe&easy
  • DE EN 中文
Results out of Read more Products View all results

Share

Share this page

You can share this page with others by sending the URL of the selected page.

email LinkedIn
Bowdencables incl. accessory Type A (Snap-in mounting) Phase-out␍Last Order date: 30.06.2017␍Last delivery date: 30.09.2017
Type A (Snap-in mounting)
Phase-out␍Last Order date: 30.06.2017␍Last delivery date: 30.09.2017
Bowdencables incl. accessory Type B (Screw-on mounting) Phase-OutLast order date: 31.03.2015
Type B (Screw-on mounting)
Phase-OutLast order date: 31.03.2015
Bowdencables incl. accessory Type A (Snap-in mounting) Phase-out␍Last Order date: 30.06.2017␍Last delivery date: 30.09.2017
Bowdencables incl. accessory Type B (Screw-on mounting) Phase-OutLast order date: 31.03.2015

Series: Bowdencables incl. accessory

Phase_Out_Logo

Bowden Cable for Power Entry Modules

Description Bowdencables incl. accessory

Description

  • Component: Snap-in mounting from front side:
  • Approved together with power entry module

Characteristics

  • Designed for universal industrial applications

Remote Actuator Technology The remote actuator cable assembly consists of a wire cable inside of a plastic insulated spiral wire casing. Identifying a proper outing of the cable assembly is important. Deviations from line to line placement will require bends in the cable with resulting losses in the overall assembly. These inefficiencies show up as friction losses and lost motion. Frictional losses are increases in actuation force due to losses in the assembly. Lost motion is an undesirable difference between the input end of the assembly and the output end. The principle element of lost motion is backlash and deflection. Backlash is caused by the wire cable moving inside the casing with the change in direction of motion. It is the function of clearance between the wire cable and casing, plus the number of degrees of bend in the cable assembly. Deflection of the cable assembly, while usually low, can be minimized by anchoring the casing. This is especially true in those applications of cable assemblies with long lengths and/or large degrees of bend in the system. All of these losses and resulting inefficiencies can be reduced by the equipment designer through minimizing the total degress of bend in the assembly. Because of the number of variables effecting proper operation of any remotely actuated switch assembly, it is important that the ordering instructions be used to determine proper cable length and to provide samples for customer approval. Consult figure for minimum information required to describe cable assembly application. How to specify length of a Bowden cable: R Mounting parallel to direction of actuation␉S Mounting 90° to direction of actuation B1 Actuating part␉␉␉␉B1 Actuating part B2 Power entry module␉␉␉B2 Power entry module ____________________________␉␉_____________________________ R a / b / ␉␉␉c / S a/ b/ c/ Ordering example: The following 3 positions are necessary to place an order: 1. Order No. socket KD14.4199.151 2. Order No. fuse drawer 4303.2024.03 3. Bowden cable (type of mounting /dimensions in mm) *R a/200 b/180 c/40 * The Order No. for a customer specific Bowden cable you’ll get with the acknowledgment. Delivery time for a customer specific Bowden cable sample approx. 2 weeks. Standard Bowden cable sample, Order No. 0886.0101, ex stock

Date Subcategory Language Title Download
21/02/2019
Flyers English Flyer Components and Solutions for Medical Equipment
20/04/2016
PCS English Bowden Cable Typ B2 without button
20/04/2016
PCS English Bowden Cable Typ B1
20/04/2016
PCS English Bowden Cable Typ B2

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals
SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.
Partners IEC_Certification_Body Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.
Environment_Safety Medical.jpg SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 

Comment CAD drawings are for modeling purposes only

Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

Bowdencables incl. accessory Bowdencables and accessories
0886.0101

Dimension [mm]

Type A (Snap-in mounting)
Dimension A will be evaluated and defined in trials by SCHURTER based on customer information a, b and c. (See Type R and Type S diagram below.)
Type B (Screw-on mounting)
Dimension A will be evaluated and defined in trials by SCHURTER based on customer information a, b and c. (See Type R and Type S diagram below.)
Panel cutout for snap-in mounting

Panel cut-out for screw version


Assembly Instructions

Drop bowden barrel into seat of switch
Slide clamp around cable
Bowden cable locked into assembly
Type R

Type R


R Mounting parallel to direction of actuation
B1 Actuation part
B2 Power entry module
Dimensions in mm (center of mounting Ø [B1], outer surface to center of mounting Ø [B2] outer surface)
Type S

Type S


S Mounting 90° to direction of actuation
B1 Actuating part
B2 Power entry module
Dimensions in mm (center of mounting Ø [B1], outer surface to center of mounting Ø [B2], outer surface)


us.schurter.com
en
en
eng-GB
prod //cdn.schurter.com