1-stage filter for 3-phase systems with neutral conductor, DIN rail mounting

4 Variants


Description FMAD RAIL

Description

  • 3 phase line filter with standard attenuation
Date Subcategory Language Title Download
24/11/2017
White Paper English White Paper Leakage currents

Rated Current

Rated Current


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

3 - 20 A @ Ta 40 °C

Rated voltage

Rated Current


The electrical characteristics describe the approved operating values for the state of rated current and rated voltage considering the mentioned conditions.

General information on electrical characteristics colors of fuses
Ratings IEC, UL/CSA

General information on the rated current and the rated voltage at EMC products
Rated Voltage
Rated current

The values are different depending on the approval body and therefore are referenced in the corresponding admission cards for the respective product families. Details about the approvals and ratings are listed in the data sheets.

Search approval information for different families

Approvals

277/480 VAC, 50/60 Hz

Approval for

Approval for


Approvals indicate the conformity of the products with the national testing institution requirements by listing of the relevant approval logos.

The link leads you to the search mask where you can query for certificates of the selected products.
Approvals

Detailed information about Approvals will be documented in the general product informations.
Details about Approvals

3 - 20 A / 277/480 VAC

Overload Current

1.5 x Ir

Leakage Current

Leakage Current


The leakage current is an electric current flowing in an undesirable current path. In EMC filters this is done by the applied Y-capacitors, which are used for noise suppression. Information on the amount and classification of leakage currents are explained in detail and are listed in the data sheets.
Leakage Current

standard < 0.5 mA (440 V / 50 Hz)

Dielectric Strength

Dielectric Strength


Information abou the maximum permissible voltage, to avoid a voltage breakdown due to insulation damage.

Dielectric Strength

277/480 VAC:
2.25 kVDC between L-L
1.7 kVDC between L-N
3 kVDC between L-PE
Test voltage (2 sec)

Number of Filter Stages

Filter Stages


Quality of a filter

1-stage

Weight

 0.4 kg

Material: Housing

Metal 

Sealing Compound

UL 94V-0 

Mounting

DIN rail mounting 

Terminal

Terminal


AMP = standardized connector systems and contacts
Abbreviation for "Zero Insertion Force". The so-called ZIF connector takes the flexprint cable without effort, mostly with locking. The advantage of this connector is the gentle treatment of the pin

Bolts and nuts M4, Quick connect terminal for PE 

Operating Temperature

-25 °C to 100 °C

Climatic Category

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

25/100/21 acc. to IEC 60068-1

Degree of Protection

Climatic Category


Disposition of components in categories for the assessment of mechanical and electrical properties.
Climatic Category

IP20 acc. to IEC 60529

Protection Class

Protection Class


Class I: with ground; Class II: without ground

Detailed information relating to protection class can also be found in the general product information

Insulation cover

Suitable for appliances with protection class I acc. to IEC 61140

MTBF

MTBF


The term MTBF is the English acronym Mean Time Between Failure and describes reliability of a component. The operating time of a system can be calculated based on thementioned value of the component. - The higher this value, the more reliable the component.
MTBF

> 200'000 h acc. to MIL-HB-217 F

Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in  Details about Approvals

SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER.


Approvals

The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.


Approval Reference Type: FMAD

Approval Logo Certificates Certification Body Description
Approval marks ENEC 10 VDE Certificate Number: 40030736
Approval marks cURus UL UL File Number: E72928


Application standards

Application standards where the product can be used

Organization Design Standard Description
Partners IEC_Certification_Body Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment.


Compliances

The product complies with following Guide Lines

Identification Details Initiator Description
Approval marks CE Selbsteklaration SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008.
Environment_Safety RoHS_Logo_color_CMYK_tif SCHURTER AG EU Directive RoHS 2011/65/EU
Environment_Safety China_RoHS_e_konform_eps SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS.
Environment_Safety REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force.

Preview
 

Picture(s) Selection of product pictures to display a specific variant of the type

Type
 

Type Corresponds to a product series and includes various distinct variants. On the type of descriptive data are summarized, eg in the data sheet

Order Number
 

Order Number Unique part number for placing an order

Configuration key
 

Configuration key The configuration key of a product consists of the composite key values, which describe the different kinds of attribut distinction.

Comment
 
Model Description
 

Model Description Abbreviated description of the CAD model

IGS
 

IGS Also mentioned as IGES ( Initial Graphics Exchange Specification). Common program indipendent interchange format for 3D CAD data.

Step
 

Step Also mentioned as STEP ( Standard for the Exchange of Product Model Data). Common program indipendent interchange format for 3D CAD data standardized according ISO standard.

Parasolid
 

Parasolid Parasolid modeling kernel is a 3D CAD systems. It is developed by a separate business unit within the Unigraphics Solutions (UGS), now Siemens PLM Software.

DXF
 

DXF (Drawing Interchange Format) is a specified by the Autodesk file format for CAD data exchange, and was developed for the 2D-CAD program AutoCAD. A DXF file describes a CAD model as plain text to the ASCII standard.

FMAD RAIL
FMAD-MRYB-1010 FMAD-MRYB-2010 FMAD-MRYB-0310 FMAD-MRYB-0610

Dimension [mm]

1) Line
2) Load
3) Tightening torque 0.6-0.8 Nm, Screw 4mm²
4) Quick connect terminal 6.3x0.8mm

Diagrams

1) Line
2) Load

Technical data to the filter components

Rated Current [A] Rated Voltage [VAC] L [mH] C1 [nF] C2 [nF] Filtertyp
           
10 277 - 480 0.4 100 4.7 Industrial Version
20 277 - 480 0.15 100 22 Industrial Version
3 277 - 480 1 100 4.7 Industrial Version
6 277 - 480 0.5 100 4.7 Industrial Version

Attenuation Loss

3 A

6 A

10 A

20 A


Short Table of Variants FMAD RAIL Open complete table FMAD RAIL


Rated Current [A] Tripped Power Dissipation [W] Leakage Current [mA] @ 440V, 60Hz 1) Order Number

Variant Details


The link on the respective order number refers to a separat tab with specific detailed information .

This assures better readable information of the selected product.
Change to the tab All Products in order to show details of another variant.

This approach offers to use generic alias link to the product details:

www.schurter.xx/art/ [Order Number]

where the following variables are used:
- xx is the country specific domain
- [Order Number]

A=Most Popular

A=Most Popular


Most popular products have the following customer benefits:

- previously ordered by multiple customers
- generally in stock for immediate delivery
- early adoption or mature life cycle

Contact us for availability on other product variants, lead-times vary:
Contact-Form

Availability for all products can be searched real-time. Enter part number and required quantity:
Stock Check SCHURTER

Free Sample

Free Sample


Please ask for free sample in order to check if the products meets your requirement for your application. Send your delivery adress and your specific requirements.

Distributor Stock Check

Distributor Stock Check


The following links reffers to the inquiry form for distributors stock information of the selected products. It allows checking for the available amount and optionally to place an order at your selected partner.

The
Distributor Stock Check
Stock Check Distributor

...
 
10 3.2 0.02 FMAD-MRYB-1010  A  ...
20 5.8 0.08 FMAD-MRYB-2010  A  ...
3 1.4 0.02 FMAD-MRYB-0310 ...
6 1.7 0.02 FMAD-MRYB-0610 ...

Most Popular.

1) Nominal leakage current acc. to IEC60950 - 5.2.5. under normal operating conditions. Note: worst case leakage current acc. to IEC60950 - Annex G4 (situation with two interrupted lines) can be much higher.

2) Maximum conductor cross section (wire gauge) to be used; a comparative table for AWG and mm² values can be found in the general product information www.schurter.com/emc_info